Model 202 Ozone Monitor:  Federal Equivalent Method (FEM)

Picture
The Model 202 Ozone Monitor is designed to enable accurate and precise (±1.5 ppb) measurements of ozone ranging from a few ppb to 100,000 ppb (0-100 ppm) based on the well established technique of UV absorbance at 254 nm. The Model 202 is light weight (2.1 kg.) and has a power consumption of only 4 watts. It can be used in almost any application where much larger ozone monitors have been used in the past and in many environments where measurements using traditional ozone monitors are impossible. The Model 202 has been certified by the EPA as a Federal Equivalent Method (FEM): EQOA-0410-190 The Model 202 has been used for the past decade in ozone monitoring networks of the U.S. National Park Service and National Forest Service. It also is widely used by NOAA, EPA, Environment Canada and the British Antarctic Survey for studies of ground-level ozone.  Download Brochure

Model 205 Dual Beam Ozone Monitor:  Federal Equivalent Method (FEM)

Picture
The Model 205 Dual Beam Ozone Monitor™ was designed for even higher precision and faster response time than our popular Model 202. Data may be output as frequently as every 2 s, making it ideal for vertical profiling using balloons or aircraft measurements where high temporal resolution is required. For a given averaging time, the Model 205 has a higher precision (better than 1 ppb for 10 s averaging) and a more stable baseline than the Model 202. The Model 205 has all of the features of the Model 202 single beam instrument, including a real time clock; averaging times of 10 s, 1 min, 5 min and 1 h; an internal data logger; serial and analog data outputs; and a backup air pump to protect against data loss in the field. The Model 205 Ozone Monitor has been designated as a Federal Equivalent Method (FEM) by the EPA.  Download Brochure

Model 211 Scrubberless Ozone Monitor: World's Most Accurate Ozone Monitor

Picture
The new Model 211 Scrubberless Ozone Monitor uses the proven ultraviolet (UV) absorption method in combination with an innovative gas-phase scrubber technology to measure ozone virtually free from interferences. In the reference mode, the instrument uses the reaction between ozone and nitric oxide (NO) to selectively remove ozone from the sample. The instrument is ideally suited for measurements of ozone in heavily polluted air where interference is likely from particulates, mercury, or VOCs. The new Model 211 combines the stability of our proven dual beam ozone monitors with our selective scrubber technology to provide highly accurate ozone measurements in the most polluted air. The Model 211 Ozone Monitor is in the process of being designated a US EPAFederal Equivalent Method (FEM).  Download Brochure

Personal Ozone Monitor™ (POM™)

Picture
2B Tech has taken the next step in miniaturization of UV-based ozone monitors by developing the Personal Ozone Monitor or "POM". The POM has dimensions of 4 x 3 x 1.5 inches and weighs only 0.75 lb (340 g). It has a built in GPS so that ozone measurements may be logged continuously along with geographic location. By folding the optical path in the shape of a "U", it was possible to achieve the same path length in the POM as in the Models 202, 205 and 106-L and thus have similar precision and accuracy (~2 ppb). The POM is ideal for personal ozone exposure studies and health and safety monitoring in workplaces where ozone is produced.   Download Brochure

Model 106-L, -M and -H Ozone Monitors for Industrial Applications

Picture
For industrial ozone applications, 2B Tech recently introduced the Model 106-L, 106-M and 106-H Ozone Monitors, where L, M and H refer to Low (0-100 ppm), Medium (0-1000 ppm) and High (0-20 wt%) ozone concentrations, respectively. These instruments use optical benches of different lengths in order to acommodate this extremely wide range of ozone concentration, spanning more than eight orders of magnitude. Additionally, the Model 106-H was designed with a flow through path that can be pressurized for in-line measurements with ozone generators. The Model 106 series uses our "Ozone Monitor on a Board" technology to make the instruments more compact and less expensive to manufacture, thus reducing the cost to our customers. The 106 series is also available for OEM applications (see panel below) and is available in water-proof NEMA boxes for harsh enviornments.  Download Brochure

Model 106 OEM Ozone Monitors

Picture
For OEM applications where users want to integrate their ozone monitor into a complex system such as an air pollution measurement package, we offer an "Ozone Monitor on a Board™" solution. The entire ozone monitor is mounted on a single printed cricuit board. The liquid crystal display and power switch may be removed and mounted outside the package if desired. The OEM board may be purchased with one of three different optical benches to optimize measurements in three different concentration ranges as follows:

OEM-106-L 0-100 ppm with 0.0001 ppm (0.1 ppb) resolution
OEM-106-M 0-1,000 ppm with 0.01 ppm resolution
OEM-106-H 0-20% by weight with 0.01% resolution

Download Brochure

Model 306 Ozone Calibration Source

Picture
The Model 306 Ozone Calibration Source is a highly portable ozone transfer standard that may used to calibrate any ozone monitor or sensor. Ozone is generated at any chosen concentration in the range 0-1000 ppb in ozone-scrubbed ambient air at a volumetric flow rate of 3 L/min. No external air source is requried. The instrument may be programmed to output a series of up to 10 ozone concentration steps with a chosen time interval. The Ozone Calibration Source is provided with a NIST-traceable calibration, and the menu allows the user to calibrate the output to their own reference instrument. This Ozone Cal Source, which qualifies as an EPA transfer standard, is particularly useful for calibrating networks of ozone monitors in the field.  Download Brochure

Global Ozone (GO3) Project Instrument Package

Picture
The GO3 Instrument Package provides everything needed for continuous measurements of ozone and meteorological parameters and the capability to upload those data to the GO3 database where measurements are displayed on an overlay in Google Earth. Measurements include ozone, temperature, barometric pressure, humidity, wind speed, wind direction and rainfall. The package includes the GO3 Ozone Monitor with a silent, long-life pump, Davis weather station, weather station mounting stand, notebook computer with data collection and uploading software installed, 50 feet of Teflon-lined Tygon inlet tubing, external ozone zeroing cartridge, external battery and charger for personal ozone monitoring, filter holder and pack of 10 Teflon particle filters, associated cables and power packs, and operating manuals.  Download Brochure

Model 410 Nitric Oxide Monitor

Picture
The Model 410 Nitric Oxide Monitor measures NO in the range 0-2,000 ppb (0-2 ppm) with a precision of ±1.5 ppb. The NO Monitor is based on our patented method of continuous titration with ozone where the depletion of ozone is measured using the absolute method of UV absorbance. An advantage over the chemiluminescence method is that only infrequent calibration is required. The Model 410 may be used in combination with the Model 401 NO2 Converter to measure NOx and NO2 (by difference) in addition to NO. Measurements are made every 10 s, and data may be internally averaged for 1 min, 5 min or 1 hr and stored in the internal data logger. Because of it's smaller size and relatively low power requirement, the Model 410/401 combination is ideal for the application of roadside monitoring and for measurements of NO/NOx in remote locations.  Download Brochure

Model 401 NO2 Converter

Picture
The Model 401 NO2 Converter™ is a portable, heated molybdenum converter for converting NO2 to NO. When air is sampled through the NO2 Converter, the Model 410 Nitric Oxide Monitor measures NOx (NO + NO2). As in chemiluminescence instruments, the NO2 concentration is obtained from the difference in the NOx and NO measurement. This approach to NO2 measurements has long been used in EPA-approved chemiluminescence instruments. The NO2 Converter also has an internal zeroing cartridge for measurement of the instrument baseline. Periodic measurements of NO, NOx and the zero are programmable through the Model 400 NO Monitor.  Download Brochure

Model 408 Nitric Oxide Calibrator

Picture
The Model 408 NO Calibration Source™ is a highly portable source of nitric oxide in the range 0-1000 ppb. The Model 408 may be used to calibrate any nitric oxide monitor, including those based on chemiluminescence. In addition to the calibration of instruments used for air monitoring, an important application is the calibration of nitric oxide breath analyzers such as the Aerocrine NIOX® and NIOX MINO® used for diagnosis and evaluation of asthma patients. The NO Cal Source produces nitric oxide in NO-scrubbed ambient air by photolysis of nitrous oxide provided by small N2O ("Whippit")cartridges or from a lecture bottle. The calibration gas is supplied at an output flow rate of 3 L/min. The instrument may be programmed to output a series of up to 10 NO concentration steps with a chosen time interval.  Download Brochure